How do you choose the stainless grade for a chemical?
From what the tank will hold, its concentration and its temperature. Send us the product details and safety data sheet and we recommend 304, 316, 316L or a higher alloy.
Do you build tanks for fuel and petroleum products?
Yes. We build fuel and petroleum tanks with fittings suited to the product and bunding connections for your site.
How are chemical tanks tested?
Hydrostatic testing (depending on the size of the tank) or air pressure testing, plus dye penetrant testing and a pre-delivery inspection, all in our workshop. Radiography and other tests your specification calls for are arranged through NATA-accredited third parties. The results go into your manufacturer's data report.
Which standards are your chemical tanks built to?
We design to the standard that applies to your product and site, including AS 1692 for flammable and combustible liquids, API 650 and API 620 for storage tanks, and AS 1210 for pressure vessels. Welding is to AS/NZS 1554, with procedures qualified to AS/NZS 3992 and ASME IX.
Can you build safety rails and access onto the tank?
Yes. We build safety rails, guides and operator platforms onto the tank in our workshop.
Can you build a chemical tank to our drawings?
Yes. We can build to your drawings or design the tank for you, with 3D modelling and approval drawings either way.